
Using Technician Interface Scripts
2-266
Sample Display – show fddi system errors
FDDI Module System Errors:
----------------------------
Port Internal
Parity Ring Operation Operation Host
Slot Conn Circuit Errors Errors Errors Errors Errors
---- ---- ------- ---------- ---------- ---------- ---------- ----------
2 1 F21 0 0 0 0 0
3 1 F31 0 0 0 0 0
2 entries in table.
transmit errors
[
circuit
<circuit name>
]
Displays statistical information about transmission errors for all circuits or for a specific
circuit. The table includes the following information:
Parity Errors Number of parity errors. Parity errors may indicate faulty
hardware. If this count exceeds five, call your customer service
representative.
Ring Errors Number of ring errors.
Port Operation Errors Number of DMA controller port operation errors. Port operation
errors may indicate faulty hardware. If this count exceeds five, call
your customer service representative.
Internal Operation Errors Number of internal operation errors.
Host Errors Number of parity errors occurring when the host driver accesses a
register on the DMA controller. Host errors may indicate faulty
hardware. If this count exceeds five, call your customer service
representative.
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Comentários a estes Manuais