Using Technician Interface Scripts
2-568
enabled
Displays SYNC circuits that a user has manually enabled. For definitions of the columns
in the table, see the
alerts command. State can also be Up.
Sample Display – show sync enabled
SYNC Modules Enabled:
---------------------
Line WAN Loc Rem Med
Slot Conn Circuit State MAC Address Number MTU Protocol Adr Adr Typ
---- ---- ------- -------- ----------------- -------- ---- -------- --- --- ---
5 1 S51 Up 00-00-A2-00-A1-73 00205101 1600 WF STND 7 7 STD
5 2 S52 Up 00-00-A2-00-A1-74 00205102 1600 WF STND 7 7 STD
Found 2 matches out of 2 entries in table.
receive errors [circuit
<circuit name>
]
Displays receive errors for all circuits or for a specific circuit. The table includes the
following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
Bad Frames Number of bad receive frames, caused by Frame Check Sequence
(FCS) errors or nonoctet aligned errors.
Runt Frames Number of runt frames received on this line.
Frame Rejects Number of frame reject errors received on this line.
Frames Too Long Number of frames received on this line that exceed the MTU.
Overflow Frames Number of overflow errors received on this line in which the
device’s FIFO buffer overflowed before obtaining the next DMA
cycle. No buffer resources are available.