Using Technician Interface Scripts
2-256
hwfilters
Displays status and statistical information about the hardware filters in use, if any. The
table includes the following information:
Sample Display – show fddi hwfilters
Hardware Filters Modules:
-------------------------
Line Maximum Current Used Dropped
Slot Conn Circuit State Type Tbl Siz Tbl Siz Entries Frames
---- ---- ------- -------- ------ ------- ------- ------- ----------
Found 0 matches out of 4 entries in table.
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier; ranges from 1 to 4.
Circuit Name of the circuit associated with this line.
State State of the filtering hardware on the line: Down, Full or Up.
Line Type FDDI.
Maximum Tbl Siz Maximum number of table entries that a line can use, based on the
hardware filter devices present and available.
Current Tbl Siz Current capacity of the hardware filter table. The protocol
dynamically allocates hardware filter table resources as needed in
increments of 256 up to the available table size.
Used Entries Number of hardware filter table entries used.
Dropped Frames Number of frames dropped because they matched the hardware
filter.