show atmsig
2-81
Sample Display – show atmsig saal
ATM SAAL Entry Table (SSCOP)
----------------------------
Arbi- Poll Alive NoResp CnCtrl MaxCn Max Ver-
Line Circuit State tration Timer Timer Timer Timer Ctrl MaxPd Stat sion
------- ------- ------ ------- ----- ----- ------ ------ ----- ----- ---- -----
1405101 A51 Up Active 7 20 70 10 4 25 67 UNI30
-------------------------------------------------------------------------------
Total entries: 1
sig [
<line>
]
Displays all instances in the ATM Signaling Entry Table, or a specific instance.
The table displays the following information:
Arbitration Determines if the SAAL initiates link connections or waits for
connections: Active or Passive.
Poll Timer SSCOP Poll Timer value (in tenths of a second).
Alive Timer Keep Alive Timer value (in tenths of a second).
NoResp Timer No Response Timer value (in tenths of a second).
CnCtrl Timer Connection Control Timer value (in tenths of a second).
MaxCn Ctrl Maximum Connection Control Timer value.
MaxPd SSCOP maximum Poll Data (PD) value.
Max Stat Maximum number of list elements allowed in a STAT PDU.
Version Version: UNI30 or UNI31.
<line>
Displays ATM Signaling information for a specific line.
Line Line number of the router.
Circuit Circuit number of the ATM driver associated with this instance.