Using Technician Interface Scripts
2-220
Sample Display – show ds1e1 fdl att1
DS1E1 Facility Data Link (FDL) Errors (first half) - AT&T-54016 mode:
---------------------------------------------------------------------
Valid Total Total Total Total Total
Slot Conn Intervals ESs SESs SEFs UASs CSSs
---- ---- ---------- ---------- ---------- ---------- ---------- ----------
2 2 1 1 0 0 368 256
Found 1 match out of 2 entries in table.
receive errors [circuit
<circuit name>
]
Displays receive errors for all circuits or for a specific circuit. The table includes the
following information:
Slot Slot identifier.
Conn Connector identifier.
Log Line Logical line number for this line.
Circuit Name of the circuit associated with this line.
Null Frames Number of frames containing no data bytes received.
Short Frames Number of frames received with only one or two data bytes.
CRC Errors Number of frames received with CRC errors.
Long Frames Number of frames received that exceeded the MTU size.
Abort Frames Number of frames received with abort errors.