Using Technician Interface Scripts
2-606
Sample Display – show token stats ring
TOKEN RING Ring Statistics:
---------------------------
Beacon Signal Auto Removes Single Cable Ring
Slot Conn Circuit Events Losses Removes Recvd Statns Faults Recvrys
---- ---- ------- ------- ------- ------- ------- ------- ------- -------
4 1 O41 0 0 0 0 3 0 1
4 2 O42 0 0 0 0 0 0 2
2 entries in table.
Sample Display – show token stats ring circuit o41
TOKEN RING Ring Statistics:
---------------------------
Beacon Signal Auto Removes Single Cable Ring
Slot Conn Circuit Events Losses Removes Recvd Statns Faults Recvrys
---- ---- ------- ------- ------- ------- ------- ------- ------- -------
4 1 O41 0 0 0 0 3 0 1
Found 1 match out of 2 entries in table.
system errors
[
circuit
<circuit name>
]
Displays statistical information about general interface errors for all circuits or for a
specific circuit. The table includes the following information:
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier: 1 or 2.
Circuit Name of the circuit associated with this line.
Adapter Checks Number of internal adapter errors that have caused adapter failures.
DMA Bus Errors Number of bus errors during DMA that do not exceed threshold.
DMA Parity Errors Number of parity errors during DMA that do not exceed threshold.
Command Timeouts Number of times a command timeout has caused the interface to
reinitialize.
Host Iface Errors Number of times a receive-host interface error has caused the
interface to reinitialize.