Configuring WAN Line Services
7-16
117345-B Rev. 00
Setting the Source of Accept Performance Messages
On DMCT1 net modules and QMCT1 or QMCT1 w/ DS0A link modules only,
you can specify the source from which the router accepts send performance
messages:
• Customer Inst -- Indicates that the router accepts messages only from the
customer installation
• Carrier -- Indicates that the router accepts messages only from the carrier
See the Accept Perf Measurement CR Addr parameter on page A-34
for
information.
Setting the Primary Clock Source
Timing is independent for the two ports on a DMCT1 net module, and for the four
ports on a QMCT1 or QMCT1 w/ DS0A link module. For these modules, you
select the timing source for each port.
Specify the primary source for timing signals:
• Internal -- Uses the clock chip on the MCT1 module
• Port 1 Ext Loop -- Uses the signal coming in from port 1
• Port 2 Ext Loop -- Uses the signal coming in from port 2
• Port 3 Ext Loop -- Uses the signal coming in from port 3 on a QMCT1
• Port 4 Ext Loop -- Uses the signal coming in from port 4 on a QMCT1
• Auxiliary Ext -- Uses an external source via port 1
See the Primary Clock parameter on page A-35
for information.
Note:
DMCE1 and DMCT1 link modules contain a single clock chip that
provides the timing signals for both ports. Therefore, clock parameters that
you set for the first port apply to the second port on the module.
Note:
External clocking via port 1 requires a special Y-cable, Bay Networks
Order No. AA0018006.