Configuring MCE1 and MCT1 Services
117345-B Rev. 00
7-9
Setting the Alarm Threshold Time
By default, the MCE1 interface waits 2 seconds before logging a performance
defect or anomaly as an event message. Change the alarm threshold to any value
from 2 to 10 seconds for this MCE1 interface.
See the Setup Alarm Threshold parameter on page A-26
for information.
Setting the Alarm Threshold Clear Time
By default, the clear time for performance-failure conditions is 2 seconds. If the
defect or anomaly clears in this time interval, MCE1 records a
performance-cleared condition and logs an event message. Change the alarm
threshold clear time to any value from 2 to 10 seconds for this MCE1 interface.
See the Clear Alarm Threshold parameter on page A-27
for information.
Enabling or Disabling the International Bit
By default, the MCE1 interface does not use the international bit in E1 frames.
Enable use of the international bit for this MCE1 interface.
See the International Bit parameter on page A-27
for information.
Setting the Line Impedance (MCE1 Net Modules Only)
The line impedance for the ASN MCE1 net module is 120 ohm by default. For the
ASN MCE1 net module only, you can change the line impedance to 75 ohm for
this MCE1 interface.
See the Line Impedance parameter on page A-27
for information.