Configuring Line Services
3-12 114078 Rev. A
To set the connection policies that you want this line to reject, you specify a status
word to a value from 0x0 through 0xffff. Start with a value of zero for the status
word (all bits set to 0).
For each connection policy that you want the node to reject, add to the status word
value the number 2 raised to a power specified in
Table 3-2. This is equivalent to
setting a bit to 1 for each policy that you want the node to reject.
Table 3-2 lists the powers and the bits for each policy range.
Figure 3-6 shows the default connection policy, status word 0xff65.
Table 3-2. SMT Connection Policy Values
Policy
Power
(Bit Number)
Policy
Power
(Bit Number)
rejectA-A 0 rejectS-A 8
rejectA-B 1 rejectS-B 9
rejectA-S 2 rejectS-S 10
rejectA-M 3 rejectS-M 11
rejectB-A 4 rejectM-A 12
rejectB-B 5 rejectM-B 13
rejectB-S 6 rejectM-S 14
rejectB-M 7 rejectM-M 15
Note: You set the status word value to reflect local connection policies.
Setting a particular connection policy does not necessarily mean that the
station will reject the connection. The SMT standard requires that both sides of
the connection must agree to reject, or else both sides must accept, the
connection. The SMT standard requires that you set Bit 15 (rejectM-M) to 1.