Avaya Configuring Line Services Manual do Utilizador Página 147

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 301
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 146
Configuring Line Services
6-22 114078 Rev. A
The router uses Flags by default. You can set the line interframe time-fill
character.
Setting the CRC Size
By default, the routers uses the 16-bit cyclic redundancy check (CRC) type. With
16-bit CRC, the router appends a 16-bit CRC to the transmitted frames and
performs a 16-bit CRC on received frames. You can change to 32-bit CRC, where
the router appends a 32-bit CRC to transmitted frames and performs a 32-bit CRC
on received frames.
You can set CRC size for the logical line.
Setting the MTU Size
The router uses the transmit/receive buffer size (MTU) to configure the largest
frame that the router can transmit or receive across this MCE1 port. The router
discards frames larger than this value. The MTU is 1600 bytes by default. You can
change it to any size from 3 through 4608 bytes for the logical line.
Enabling or Disabling Remote Loopback Detection
Setting Remote Loopback Detection enables or disables detection of the driver’s
own BofL packets, as long as the BofL Enable/Disable parameter is enabled for
this interface. If you select Enable and put the line into loopback mode, the
downstream driver will bring down the interface when it detects its own BofL
packet.
You can disable or reenable loopback detection on this interface.
Site Manager: Interframe Time Fill Character parameter: page A-41
Site Manager: CRC Size parameter: page A-41
Site Manager: MTU Size (bytes) parameter: page A-41
Site Manager: Remote Loopback Detection parameter: page A-42