Setting the Sequenced Frame T2 Acknowledge Timer
The Max T2 Acknowledge Timer specifies the time, in seconds, that the router
waits before sending an acknowledgment for a sequenced frame.
The default value of 1 means that the router does not delay before generating an
acknowledgment.
You can set the amount of time that you want the router to wait before
acknowledging a sequenced frame to a value from 1 through 9999 seconds.
Setting the T3 Disconnect Timer
The Max T3 Disconnect Timer specifies the time, in seconds, that the router waits
before determining that the link is disconnected.
By default, this timer is set to 60 seconds. A value of 1 indicates that once the
router completes the frame exchange to bring down the link, it considers the link
disconnected.
You can set the amount of time that you want the router to wait before it decides
that the link is disconnected to a value from 1 through 9999 seconds.
Setting the Link Setup Action
The Link Setup Action parameter identifies whether or not the router initiates link
setup or waits for the network to initiate.
Enter Active if you want the router to initiate link setup, or Passive if you want the
network to initiate link setup. Link Setup is Active by default.
You can set the Link Setup Action to Active or Passive.
Site Manager: Max T2 Acknowledge Timer (seconds) parameter: page A-35
Site Manager: Max T3 Disconnect Timer (seconds) parameter: page A-35
Site Manager: Initiate Link Setup Action parameter: page A-36