Site Manager Line Services Parameters
114078 Rev. A A-43
MCE1 Port Parameters
You access the MCE1 port parameters from the Configuration Manager.
Parameter: Accept Fractional Loopback Code
Path: Configured QMCT1 Connector (in Dynamic Mode) > MCT1 Logical Lines
Default: Enable
Options: Enable
| Disable
Function: Determines whether or not the logical line can accept fractional T1 loopback
code.
Instructions: Select Enable or Disable.
You can only configure this parameter for QMCT1 link modules.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.??
Parameter: Port Application Mode
Path: Unconfigured MCE1 Connector > Port Application
Default: NONPRI
Options: NONPRI
| PRI
Function: Specifies the application that the logical lines of this port provide.
Instructions: Select NONPRI to indicate that all the lines permanent circuit number and are
for leased lines, Frame Relay, or permanent connections for other non-ISDN
PRI applications.
Select PRI to indicate that the lines are for switched circuits using ISDN.
You must configure NONPRI applications for MCE1-I interfaces.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.1.16