DLSw Troubleshooting
114063 Rev. A C-3
Using and Decoding the DLSw Log
This section provides general information about DLSw states and events, as
described in RFC 1434 and RFC 1795. DLSw states and events appear as
numbers within the text of logged messages.
If a message contains the text “old state = 3, new state = 1,” the numbers 3 and 1
point to specific conditions in the DLSw state table. Similarly, a message
containing the text “event= 3,” points to a specific condition in the DLSw event
table.
Table C-2 lists the DLSw state names and numbers. Table C-3 lists the DLSw
events and numbers. Refer to these tables when decoding messages in the DLSw
log.
Table C-2. DLSw State Table
State Name State Number
CONNECTED 1
CONNECT PENDING 2
CONTACT PENDING 3
CIRCUIT ESTABLISHED 4
CIRCUIT PENDING 5
CIRCUIT RESTART 6
HALT PENDING 7
DISCONNECTED 11
DISCONNECT PENDING 12
RESTART PENDING 13
RESOLVE PENDING 14