Editing DLSw Parameters
114063 Rev. A 5-25
Parameter: Slot
Default: None
Range: 1 to 14
Function: Specifies the slot number that you want to associate with the IP interface
address that you reserved for that slot.
Instructions: Type a slot number from 1 to 14, depending on
• Type of node/chassis
• Slots that link modules can occupy
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.3.1.2
Parameter: IP Address
Default: None
Options: Any valid, 32-bit IP address in the form network.host in dotted decimal
notation
Function: Specifies an IP address associated with a specific DLSw peer slot in the
router. TCP uses this IP address for connections associated with that slot.
Instructions: Type a valid IP address for the slot. The IP interface need not reside on the
DLSw-capable slot. Do not enter a value for every active slot in the
router; enter one IP address associated with one DLSw slot.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.5.3.1.3
Editing a DLSw Slot IP Table Entry
You can edit only the IP Address for TCP Connection parameter in an existing
DLSw Slot IP Table entry.
To edit the IP address associated with a particular slot, begin at the Configuration
Manager window (
refer to Figure 5-1):
1. Select Protocols > DLSw > Slot IP Table.
The DLSw Slot Configuration window appears
(Figure 5-13).
2. Select the DLSw Slot IP Table entry.