Chapter 9 Configuring telephony resources 103
Networking Configuration Guide
The Telephony Resources table fields are described in Table 13.
Table 13 Telephony Resources table fields (Sheet 1 of 2)
Attribute Value Description
Location <read-only>
Module type <read-only>
DID4
DID8
ASM/ASM+
GATM4
DSM16
DSM32/
DSM32+
4X16 Combo
8X16 Combo
DTM-T1
DTM-PRI
CTM4/GATM4
CTM8/GATM8
BRIM
Empty
This field indicates the type of module assigned to each
location.
DID4
DID8
ASM/GASM: Analog and Global Analog Station Modules
provide four connections for four analog telephones.
GATM8: Global Analog Trunk Module with four trunk line
connections.
DSM16 or DSM32/DSM32+: Digital Station Module with 16
and 32 telephone connections, respectively.
4X16 Combo: A module with 4 analog trunks and 16 digital
stations.
8X16 Combo: A module with 8 analog trunks and 16 digital
stations.
BRI-ST
DTM-T1
DTM-PRI
Empty: No module is currently connected.
Bus <read-only>
1-XX
This number indicates the virtual bus to which the module is
assigned. For trunk modules, this position determines the
default line numbers available to the trunks attached to the
module.
For station modules, this position determines the DN range
that will automatically be assigned to telephones plugged
into the module.
State Enabled
Disabled
Unequipped
Indicates the state of the module or bus:
Enabled: module is installed and working
Disabled: module is installed but has been disabled or is
down for another reason
Unequipped: there is no module installed on this bus
Devices Set
Lines
Lists the type of device configured on the bus.
Low <digits> This field indicates the lowest setting for one of the following:
The range of lines the module/VoIP supports
The range of loops the module supports (BRI)
The range of DNs the module/IP telephony supports.
High <digits> This field indicates the highest setting for one of the
following:
The range of lines the module/VoIP supports
The range of loops the module supports (BRI)
The range of DNs the module/IP telephony supports.
Total <XX> Lines,
loops or Sets
This field indicates the total number of lines, loops or DNs
that the module supports.