Communication Manager Administration
42 Avaya Agent Deskphone 16CC Administrator Guide
Enable applicable
calling features
on the Class of
Restriction form
change cor Varied To use the Call Pickup
feature, the Can Use Directed
Call Pickup and Can Be
Picked Up By Call Pickup
fields must be set to "y" for
the affected stations. Note
that Page 3 can be used to
implement a form of
centralized call screening for
groups of stations and trunks
Add a station for
each SIP phone
to be supported
using the Station
form (page 1)
add station xxxxxx
(where xxxxxx
represents the
extension number)
Extension Assign the same extension
as the CM call server
extension administered in SIP
Enablement Services. See
Chapter 5: SIP Enablement
Services (SES)
Administration and SES
documentation for SES
configuration information.
Note: For all other Station Form (screen) page/field information, see Administering Stations on
page 43.
Stations With
Off-PBX
Telephone
Integration form
(page 1)
change
off-pbx-telephone
station-mapping
xxxxxx where
xxxxxx represents
the extension number
of the station being
configured
Station
Extension
Application
Dial Prefix
Phone Number
Trunk Selection
Configuration
Set
Use to map the
Communication Manager
extension to the same SIP
Enablement Services call
server extension. The
Application is "OPS." Enter
the other appropriate field
values, for example, the
Trunk Selection value
indicates the SIP trunk group.
The Configuration Set value
can reference a set that has
the default settings in
Communication Manager.
Stations With
Off-PBX
Telephone
Integration form
(page 2)
change
off-pbx-telephone
station-mapping
xxxxxx where
xxxxxx represents
the extension number
of the station being
configured
Call Limit Change the call limit to match
the number of "call-appr"
entries in the Add Station
form.
Table 6: CM/SIP Configuration Requirements (continued)
Task/Form Command Field(s) Value(s)
3 of 3