10-52 Error Codes
Troubleshooting
7107 Transmit Buffer overrun See receive buffer overrun (7105).
7108 Serial transmit error See serial receive error (7106).
7109 Could not communicate with
device.
Be sure the data module or
wallboard is securely plugged in.
7202 General network failure If the DEFINITY system is booting,
wait for the system to come up; retry
connecting again.
7203 Invalid destination Make sure the host name is a valid
one. If using DNS, use the fully
qualified host name.
7204 Network connection failed Make sure that the port specified is
22.
7205 Network remote reset. This error occurs when the
DEFINITY system is being brought
down (and hence the existing
connection is being forcibly closed).
Try connecting again, after the
DEFINITY system is restarted.
This error can also occur if the
network is down. Contact the
Network Administrator.
7401 Internal software error Contact Avaya.
7402 Server link timed out - the process
you were trying to contact is
missing, hung, or busy.
Be sure the process is running
properly. The missing process will
be Omninames, ConnectionServer,
or BCMS Vu Server. It may be
necessary to restart the process. If
using TCP/IP for connection to the
DEFINITY system, make sure the
IP address (if specified) is correct,
or the DEFINITY system is up and
running.
ID Description Resolution
Comentários a estes Manuais