36 Chapter 3 Installing IP Telephones
P0937663 02.0
After you have configured a telephone, it attempts to connect to the Business Communications
Manager. The message Locating Server appears on the display. If the connection is successful,
the message changes to Connecting to Server after about 15 seconds.
The IP telephone is completely booted once the date/time string is displayed on the telephone. Do
not attempt to use the telephone while the string "Connecting to server" is displayed (initialization
of the telephone may take several minutes).
Troubleshooting an IP telephone
If the system is not properly configured, several messages can appear:
SERVER: NO PORTS LEFT--The Business Communications Manager has run out of ports.
This message will remain on the display until a port becomes available and the telephone is
powered down then powered up.To obtain more ports, you may need to install additional
keycodes. See the Keycode Installation Guide.
Invalid Server Address--The S1 is incorrectly configured with the IP address of a Business
Communications Manager network adapter other than the published IP address.
NEW SET--The telephone has not been connected to the Business Communications Manager
before, and must be registered.
DEF GW Default Gateway on the network (i.e., the nearest router to the
telephone.
The router for IP address W.X.Y.Z is usually at W.X.Y.1)
If there are no routers between the telephone and the Business
Communications Manager network adaptor to which it is connected, (for
example a direct HUB connection), then enter the Published IP address
of the Business Communications Manager as the DEF GW.
If the IP telephone is not connected directly to the Published IP address
network adaptor, set the DEF GW to the IP address of the network
adaptor the telephone is connected to. For information on setting the
published IP address of the Business Communications Manager, see
Setting the Published IP Address on page 51.
S1 IP This is the Published IP address of the Business Communications
Manager.
S1 PORT Set this to 7000.
S1 ACTION Set this to 1.
S1 RETRY COUNT Set this to 255.
S2 IP This is the Published IP address of the Business Communications
Manager.
S2 PORT Set this to 7000.
S2 ACTION Set this to 1.
S2 RETRY COUNT Set this to 255.