3-34 117362-A Rev. A
To specify the maximum number of successive alarms, complete the tasks in the
following table.
Specifying Polling Intervals for Held Variables
You can specify an integer value to determine the number of exception-free
polling intervals through which a variable in a held state must pass before the
variable is no longer considered held. The lower the number you specify, the more
likely the agent is to generate repetitive event messages for a variable that is
intermittently exceeding thresholds.
To specify the number of exception-free polling intervals through which a variable
in a held state must pass before the variable is no longer considered held,
complete the tasks in the following table.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose Protocols.
The Protocols menu opens.
2. Choose Global Protocols. The Global Protocols menu opens.
3. Choose Thresholds. The Thresholds menu opens.
4. Choose Thresholds. The Thresholds Interface Lists window
opens.
5. Set the Threshold Max Successive
Alarms parameter. Click on Help or see
the parameter description on page A-
14.
6. Click on Done. You return to the Configuration Manager
window.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose Protocols.
The Protocols menu opens.
2. Choose Global Protocols. The Global Protocols menu opens.
3. Choose Thresholds. The Thresholds menu opens.
(continued)