Customizing SNMP
117362-A Rev. A 3-31
To specify the severity level for event messages, complete the tasks in the
following table.
Specifying Threshold Units
You can specify the units used to determine whether a variable has exceeded a
threshold.
• To generate a threshold event when the variable’s rate of change per second
reaches one of the three thresholds, set the Threshold Units parameter to
Persecond.
• To generate a threshold event when the value of the variable reaches one of
the three thresholds, set the Threshold Units parameter to Absolute.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose Protocols.
The Protocols menu opens.
2. Choose Global Protocols. The Global Protocols menu opens.
3. Choose Thresholds. The Thresholds menu opens.
4. Choose Thresholds. The Thresholds Interface Lists window
opens.
5. Set the following parameters:
• Threshold Low Event Level
• Threshold Medium Event Level
• Threshold High Event Level
Click on Help or see the parameter
descriptions beginning on page A-
10.
6. Click on Done. You return to the Configuration Manager
window.