Configuring Dial Services
1-8 114062 Rev. A
Terminating Demand Circuits
The router deactivates the demand circuit under one of the following conditions:
The inactivity time expires.
To deactivate the connection, you can configure the Inactivity Time
parameter, which dynamically terminates the connection after a specified
amount of time elapses without data activity. If there is data going across the
line, the inactivity timer resets and the connection remains active.
To ensure that a connection is not up longer than necessary, you can configure
traffic filters that allow specific types of data to go across a line without
resetting the inactivity timer.
You enable the Force Take Down parameter.
To deactivate a force dial connection, you configure the Force Take Down
parameter, which instructs the router to clear the connection. To learn how to
configure this parameter, refer to Chapter 8.
You schedule the circuit to come down.
Using the Schedule option, you can schedule the circuit’s availability for a
specific day and time. The schedule parameters are part of the circuit’s
configuration (refer to Chapter 8). The Schedule option also allows you to
configure whether the router uses the Inactivity Time parameter to
dynamically deactivate the connection.
Note: The router does not consider PPP’s Link Quality Report (LQR), Link
Control Protocol (LCP), and periodic CHAP messages as data, so they do not
reset the inactivity timer.