Configuring Bandwidth-on-Demand Circuits
114062 Rev. A
10-3
Figure 10-2. Circuit Options Window
3.
Enter values for these parameters, then click on OK. Refer to the
parameter descriptions that follow this procedure as guidelines.
Note the instructions for the Bandwidth Mode parameter:
a.
If you accepted the default, Non-Monitor:
Site Manager displays the Caller Resolution Info window. This window
enables you to enter the CHAP Name or PAP ID of one of the remote
routers that this circuit supports. This ensures that the local, non-monitor
router receiving the call verifies the identity of the remote router placing
the call.
Enter values for the Caller Resolution parameters according to the
descriptions in Chapter
12.
b.
If you selected Monitor:
You are not prompted for caller resolution information. However, if this is
the first Monitor circuit in a pool that uses multiple slots, Site Manager
displays the Preferred/Reserved Slots for BOD Pool window
(Figure
10-3).