Configuring Dial Services
9-24 114062 Rev. A
Parameter: Address Length
Default: Two Byte
Options: Two Byte
| Three Byte | Four Byte
Function: Specifies the length of the Frame Relay address field.
Instructions: Select the address length for the address field. This must match what the
network specifies.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.9
Parameter: Polling Interval
Default: 10 seconds
Range: 5 to 30 seconds
Function: Specifies the interval between Status Inquiry messages that the router
transmits. Status Inquiry messages cause a network response in the form
of a Link Integrity Verification message or Full Status message.
Successful completion of the request/response “handshake” verifies the
status of the router/Frame Relay network link.
Instructions: We recommend that you accept the default value, 10 seconds. If the
default value does not match what the network requests, enter a value that
is appropriate for your network in the range of 5 to 30 seconds. Polling
Interval does not function if you set the Mgmnt Type parameter to
DLCMI None.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.10
Note: The length of this field determines the range of valid numbers for the
DLCI number set in the Frame Relay PVC List window. See the DLCI
Number parameter description for more details.