Avaya Configuring Dial Services Manual do Utilizador Página 159

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 326
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 158
Creating Line Pools
114062 Rev. A 7-61
Parameter: BRI T4 Timer
Default: 750 milliseconds
Range: 500 to 1000 milliseconds
Function: Indicates the amount of time the router waits for the line to recover from a
deactivated state. This timer prevents brief, minor disturbances on a noisy
line from forcing the router to deactivate the circuit. Instead, the router
waits to see if the line recovers within the T4 timer period. This enables
the router to suppress minor line problems from the upper-layer protocols.
Instructions: Enter a time limit that the router waits for the line to come back up before
it deactivates the circuit. If your line is particularly noisy, enter the
maximum time for the router to wait for the line to reactivate.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.8.9.1.15
Parameter: BRI B Channel Loopback
Default: Disable
Options: Enable
| Disable
Function: This parameter is for Layer 1 ISDN BRI conformance testing. It allows
external equipment to send data to the router over the B channels and loop
it right back out the S/T interface. By doing this, the external equipment
can verify the physical connection between its equipment and the router.
Instructions: Select Enable if you want to run a loopback test between the network and
the S/T interface on the router. Note that you should never enable this
parameter when the router is in normal operational mode.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.8.9.1.13
Vista de página 158
1 2 ... 154 155 156 157 158 159 160 161 162 163 164 ... 325 326

Comentários a estes Manuais

Sem comentários