Avaya Configuring Dial Services Manual do Utilizador Página 214

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 326
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 213
Configuring Dial Services
9-18
114062 Rev. A
Frame Relay Primary Circuit Parameters
Use the following descriptions when you edit the primary circuit parameters.
Parameter: Backup Pool ID
Default: None
Range: 1 to 255
Function: Identifies the backup pool for the primary circuit.
Instructions: Enter the ID number of the backup pool this circuit should use.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.5
Parameter: Maximum Up Time
Default: 60 minutes
Range: 1 to 999999 minutes
Function: Specifies the maximum duration of a call for a continuous period of time.
This value ensures that the connection is not up longer than necessary.
For example, you may configure the circuit’s availability (via the Start
and End time parameters) from 9:00 a.m. to 5:00 p.m. Then configure this
parameter for 60 minutes. If the connection comes up at 10:00 a.m., the
router keeps the circuit active until 11:00 a.m. Then the router invokes the
Max UpTime Termination parameter to deactivate the circuit.
Instructions: Enter the maximum amount of time the call can last continuously.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.4.5.1.10