Avaya Using Technician Interface Scripts Manual do Utilizador Página 754

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 892
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 753
Using Technician Interface Scripts
2-706
303560-A Rev 00
stats line [circuit
<circuit name>
]
Displays Token Ring line statistical information for all Token Ring circuits or for a
specific circuit. The table contains the following information:
Sample Display - show token stats line
TOKEN RING Line Statistics:
---------------------------
ARI/FCI Frame Token Soft
Slot Conn Circuit Errors Copied Err Errors Errors
---- ---- ------- ---------- ---------- ---------- ----------
4 1 O41 0 0 0 393
4 2 O42 3 0 0 373
2 entries in table.
Slot Slot identifier; ranges from 1 to 14.
Conn Connector identifier: 1 or 2.
Circuit Name of the circuit associated with this line.
ARI/FCI Errors Number of times this station has received both an AMP MAC
frame and an SMP MAC frame with the a & c bits clear or more
than one SMP MAC frame with the a & c bits clear without an
intervening AMP MAC frame. This condition indicates that the
upstream neighbor is unable to set the a & c bits in a frame that it
has copied.
Frame Copied Err Number of frames addressed to this station that had their a & c bits
previously set.
Token Errors Number of token protocol errors; relevant only when this station is
the active monitor.
Soft Errors Number of soft errors; corresponds to the number of Report Error
MAC frames that this station has transmitted.