Sample Display - show ds1e1 receive errors circuit Boston
DS1E1 Logical Line Receive Errors:
----------------------------------
Log Null Short CRC Long Abort
Slot Conn Line Circuit Frames Frames Errors Frames Frames
---- ---- ---- ---------- --------- --------- --------- --------- --------
2 1 1 Boston 0 1256 0 0 0
Found 1 match out of 3 entries in table.
sample
[
<period in seconds>
]
[
circuit
<circuit name>
]
Displays data sampled from DS1E1 over a period of 10 seconds. You can change the
number of seconds over which you want to sample the data, and you can display sampled
data for a specific circuit only. The table includes the following information:
Slot Slot identifier.
Conn Connector identifier.
Log Line Logical line number for this line.
Circuit Name of the circuit associated with this line.
Rx Frames Number of frames received on this line.
Tx Frames Number of frames sent on this line.
Rx Lack of Resources Number of packets received and discarded because of lack of
resources; for example, CPU is overworked.
Tx Lack of Resources Number of transmit packets discarded because of lack of resources; for
example, transmit queue length is too small.