Sample Display - show dsx3 ccts
DSX3 entries:
------------
Sec into # of Line
Circuit Name Index Interval Intervals Coding Line Type Status
------------ ------- -------- --------- ------ --------- -------
A41 1404101 704 68 HDB3 E3_other NoAlarm
A61 1405101 705 68 B3ZS DS3_M23 NoAlarm
Line Type The line type of this circuit. The line type indicates the variety of
DS-3 C-bit or E-3 applications implemented on the interface.
The type of interface affects the interpretation of the usage and
error statistics. The options are
DS3_M23 (ANSI T1.107-1988)
DS3_Cbit (ANSI T1.107a-1989)
•E3_framed (CCITT G.751)
E3_plcp (ETSI T/NA[91]18)
Status The line status of the interface. The possible status variables are
NoAlarm - no alarm present
RRAI - receiving yellow remote alarm indication
TRAI - transmitting yellow remote alarm indication
RAIS - receiving Alarm Indications Signal (AIS) failure state
TAIS - transmitting AIS failure state
LOF - receiving Loss of Frame (LOF) failure state
LOS - receiving Loss of Signal (LOS) failure state
Loopback
- looping the received signal
TestCode - receiving a test pattern
LowSignal - low signal