Using Technician Interface Scripts
2-14
303560-A Rev 00
For more information about COS types and weight, see the cos node command.
Byte Cst Max Maximum cost of transmitting a byte over this connection. Range is
from 0 (lowest cost) to 255.
Security Min Minimum security, with security represented as an integer with a range
of 1 through 255: 1 (nonsecure), 32 (public switched), 64
(underground), 128 (conduit), 160 (encrypted), 192 (guarded
radiation), 255 (maximum).
Security Max Maximum security, with security represented as an integer with a range
of 1 through 255: 1 (nonsecure), 32 (public switched), 64
(underground), 128 (conduit), 160 (encrypted), 192 (guarded
radiation), 255 (maximum).
Delay Min Minimum amount of time that it takes for a signal to travel the length of
the logical link, with a range of from 0 to 255: 76 (negligible), 113
(terrestrial), 145 (packet), 153 (long), 255 (maximum).
Delay Max Maximum amount of time that it takes for a signal to travel the length
of the logical link, with a range of from 0 to 255: 76 (negligible), 113
(terrestrial), 145 (packet), 153 (long), 255 (maximum).
User-1 Min First minimum user-defined transmission group characteristic for this
transmission group with a range of from 0 to 255.
User-1 Max First maximum user-defined transmission group characteristic for this
transmission group with a range of from 0 to 255.
User-2 Min Second minimum user-defined transmission group characteristic for
this transmission group with a range of from 0 to 255.
User-2 Max Second maximum user-defined transmission group characteristic for
this transmission group with a range of from 0 to 255.
User-3 Min Third minimum user-defined transmission group characteristic for this
transmission group with a range of from 0 to 255.
User-3 Max Third maximum user-defined transmission group characteristic for this
transmission group with a range of from 0 to 255.