Avaya Using Technician Interface Scripts Manual do Utilizador Página 284

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 892
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 283
Using Technician Interface Scripts
2-236
303560-A Rev 00
DS1E1 FDL Errors -- AT&T-54016 mode (first half):
Sample Display - show ds1e1 fdl att1
DS1E1 Facility Data Link (FDL) Errors (first half) - AT&T-54016 mode:
---------------------------------------------------------------------
Valid Total Total Total Total Total
Slot Conn Intervals ESs SESs SEFs UASs CSSs
---- ---- ---------- ---------- ---------- ---------- ---------- ---------
2 2 1 1 0 0 368 256
Slot Slot identifier.
Conn Connector identifier.
Valid Intervals Number of previous time intervals for which valid data was collected.
The value is 96 unless the interface was brought on line within the last
24 hours. In this case, the value is the number of complete 15-minute
intervals since the interface has been on line.
Total ESs Number of Errored Seconds that a DS1 interface encountered in the
previous 24-hour interval.
Total SESs Number of Severely Errored Seconds that a DS1 interface encountered
in the previous 24-hour interval.
Total SEFs Number of Severely Errored Framing Seconds that a DS1 interface
encountered in the previous 24-hour interval.
Total UASs Number of Unavailable Seconds that a DS1 interface encountered in
the previous 24-hour interval.
Total CSSs Number of Controlled Slip Seconds that a DS1 interface encountered in
the previous 24-hour interval.
Vista de página 283
1 2 ... 279 280 281 282 283 284 285 286 287 288 289 ... 891 892

Comentários a estes Manuais

Sem comentários