Parameter: MIB II Counters Enable
Attribute Name: wfSysMibCounterEnable
Attribute Number: 12
Default: 1 (Enable)
Options: 1 (Enable)
| 2 (Disable)
Enables or disables the following five counters in the MIB for Version
8.10 and later router software:
ifInUcastPkts
ifInNUCastPkts
IfINUnknownProtos
ifOutUcastPkts
ifOutNUcastPkts
Instructions: Set to 1 (Enable) to enable the five counters on all circuits and slots. Set to
2 (Disable) to disable the counters on all circuits and slots.
Command:
set wfSys.12.0
<option>
MIB Object ID: 1.3.6.1.4.1.18.3.3.1.12