Customizing TDM
309426-14.10 Rev 01
2-9
To set the service category to CBR, navigate to the ATM PVC prompt (for
example,
box#;atm/1/1/2/1;pvc-service/ces1422;pvc/32/33), and enter:
service-category cbr
7.
Connect a dual synchronous connector to an ATM PVC.
To connect the dual synchronous connector to the ATM PVC, navigate to the
ATM PVC prompt (for example,
box#;atm/1/1/2/1;pvc-service/
ces1422;pvc/0/130
) and enter:
ces sslot
<slot_number>
spci-slot
<pci_number>
smodule
<mod_number>
sconnector
<conn_number>
connect sslot
<slot_number>
spci-slot
<pci_number>
smodule
<mod_number>
sconnector
<connector_number>
slot_number
is the slot number containing the dual synchronous module. The
slot number for the dual synchronous module is always 1.
pci_number
is the number of the pci-slot containing the dual synchronous
board.
smodule_number
is a convention used within the Passport 5430 chassis.
connector_number
is the connector associated with this interface.
For example, to connect an ATM PVC, located at slot 1, pci-slot 1, module 2,
connector 1 with a VCI/VPI pair of 32/33, to the dual synchronous connector
located at slot 1, pci-slot 4, module 2, connector 2, enter the following
command:
pvc/1/1/2/1/32/33#
ces 1/4/2/2
Using Site Manager
To make a CES H.110 TDM circuit connection, complete the following tasks:
1.
Configure a dual synchronous board.
Site Manager Procedure
You do this System responds
1. In the Site Manager window, click on
Configuration Manager
.
The Open Configuration File window
opens.
2. Specify a configuration file name and click
on
Save
.
The Select Router Model window opens.