2-600 117380-A Rev. A
configuration [
<object ID>
]
Displays configuration information for all objects or for a specific object. The table
includes the following information:
Sample Display - show sta configuration
Statistical Thresholds and Alarm Configuration
----------------------------------------------
Object = 1.3.6.1.4.1.18.3.4.1.1.24.2.1
Threshold
State State Low Medium High Current Action
--------- ---------- ---------- ---------- ---------- ---------- ------------
Enabled Valid 12 20 60 0 Greater than
Object Identifier of the MIB object to examine for threshold exceptions.
State Operating state of the threshold: Enabled or Disabled. When State
is Disabled, the router ignores the threshold during its polling.
Threshold State Threshold state: Valid, Ignored, Held, Suspended, or Invalid.
Low Level of low threshold for this statistic. This is the level at which
the system generates a low-threshold exception event.
Medium Level of medium threshold for this statistic. This is the level at
which the system generates a medium-threshold exception event.
High Level of high threshold for this statistic. This is the level at which
the system generates a high-threshold exception event.
Current Most recently computed threshold value for the polled object.
Action How to evaluate the threshold with respect to the threshold values:
Greater than - Generates threshold events when the value of the
statistic is greater than the thresholds specified.
Less than - Generates threshold events when the value of the
statistic is less than the thresholds specified.