Using Technician Interface Scripts
2-390 117380-A Rev. A
Sample Display - $show iredund circuit
Interface Redundancy Circuit Table
-------------------------------
Circuit Slot Port State Role Active
-------- -------- -------- ------------ ---------- ----------
E43 4 3 Enabled primary standby
E43 4 4 Enabled backup active
2 Entries found.
disabled
Displays all disabled circuits that contain an interface redundancy port. A circuit is
disabled if the disable/enable parameter is set to disable and the state is down. For
definitions of the columns in the table, see the
circuit command.
Sample Display - $show iredund disable
Interface Redundancy Circuit Table
-------------------------------
Circuit Slot Port State Role Active
-------- -------- -------- ------------ ---------- ----------
0 Entries found.