NCD Alarms
The NCD alarms display the alarm/diagnostics messages sent from the Network
Interface Controller (NIC) and the redundant backup controller.
NCD 10004
NIC Loss of Reference Clock A to PLL
• There is no longer a redundant reference clock (clock A) available for the
Phase Locked Loop. See “NIC Phase Lock Loop (PLL)” on page 441.
NIC Loss of Reference Clock B to PLL
• There is no longer a redundant reference clock (clock B) available for the
Phase Locked Loop. See “NIC Phase Lock Loop (PLL)” on page 441.
NIC_PLL No Reference Clock Available for PLL. Cannot
perform inter-TMS bridging
• There is no longer any reference clock available (either A or B) for the Phase
Locked Loop. See “NIC Phase Lock Loop (PLL)” on page 441.
NIC_Monitor Detected failure on Secondary NIC
• The Primary NIC has lost connection with the secondary NIC. See “NIC
Redundancy” on page 441.
NIC Loss of data integrity on ATM fiber
• There is a failure on one of the fiber connections. This can affect inter-chassis
bridging and PCM audio functions. See “NIC ATM” on page 441.
Over Temperature Condition exists on a NIC
• The NIC hardware is no longer in the normal operating temperature range.
See “Temperature” on page 442.
The following messages indicate that the previous error conditions are clearing/have
cleared.
NIC_PLL Reference Clock A is available to PLL. Inter-TMS
bridging can now be performed
NIC_PLL Reference Clock B is available to PLL. Inter-TMS
bridging can now be performed
NIC Clearing Loss of all Reference Clocks