GeoTel Features User Manual VENGINE Alarms
P0602482 Ver. 04.03 Avaya Page 223
VENGINE 25005
MESSAGE
[Para <block_name>/<1>] Endfile for '<filename>' file
SEVERITY
3
PROBABLE CAUSE
The application attempted to execute an array-read call function and the read
operation reached the end of the file. The number-of-elements parameter may be set
too high.
ACTION
If the number-of-elements parameter is valid, no action is necessary. If the number-of-
elements parameter is greater than the number of elements in the file, modify the
number-of-elements parameter to within the valid range.