Avaya Media Processing Server Series Alarm Reference Manual (Software Release 2.1) Manual do Utilizador Página 395

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 452
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 394
GeoTel Features User Manual VENGINE Alarms
P0602482 Ver. 04.03 Avaya Page 395
VENGINE 29016
MESSAGE
[Para <block_name>/
<1>] Norestart condition arrived due to soft termination
SEVERITY
3
PROBABLE CAUSE
The application was soft terminated and will not automatically restart. Soft
termination is usually initiated by a kill signal (either from PeriView or from the
kill command). This alarm does not necessarily indicate a system error.
ACTION
If the application was knowingly soft terminated, no action is required. If the
application consistently soft terminates without reason, there may be more serious
problems. Contact your local Avaya MPS support staff.