Troubleshooting Network Boot Problems
114084 Rev. A A-7
To display the drivers that are configured to run, enter the following
command:
get wfDrivers.*.0
A combination of the following settings should appear within the list of
drivers, according to your AN/ANH/ARN configuration:
Use the
set command to correct any settings that are incorrect. For
example, if the router has a Token Ring port and the
wfDrivers.wfTMS380Load.0 setting is not 2147483648, enter the
following command to correct it:
set wfDrivers.wfTMS380Load.0 2147483648;commit
• If the router is Netbooting with a synchronous connector, enter the
following command to display the information about the connector,
where <connector> is the connector number:
get wfSyncEntry.*.1.
<connector>
Make sure that external clocking is set.
• If the router is Netbooting with an Ethernet connector, enter the following
command to display the information about the connector, where
<connector> is the connector number:
get wfCSMACDEntry.*.1.
<connector>
• If the router is Netbooting with a Token Ring connector, enter the
following command to display the information about the connector,
where <connector> is the connector number:
get wfTokenRingEntry.*.1.
<connector>
wfDrivers.wfQsccSyncLoad.0 = 2147483648
COM ports
wfDrivers.wfQsccEnetLoad.0 = 2147483648
Ethernet ports
(nonrepeating)
wfDrivers.wfRptrLoad.0 = 2147483648
Ethernet repeater
ports (ANH only)
wfDrivers.wfTMS380Load.0 = 2147483648
Token Ring ports