Configuring IP Utilities
5-4 114071 Rev. A
Changing the Login Timeout
You can specify a value that will determine the number of minutes that can elapse
before the Technician Interface disconnects the Telnet session if you fail to enter a
login ID at the login prompt. By default, the Technician Interface waits 1 minute
before it disconnects the Telnet session if you fail to enter a login ID at the login
prompt.
Changing the Password Timeout
By changing the password timeout value you can determine the number of
minutes that can elapse before the Technician Interface disconnects the Telnet
session if you do not enter a password at the password prompt. By default, the
Technician Interface waits 1 minute before it disconnects the Telnet session if you
fail to enter a password at the password prompt.
Changing the Command Timeout
By changing the command timeout you determine the number of minutes that can
elapse before the Technician Interface disconnects the Telnet session if you do not
enter a command at the command prompt. The default value is 15 minutes.
Changing Login Retries
By changing the login retries you can determine the maximum number of login
attempts you can make before the Technician Interface disconnects the Telnet
session. The default value is three login attempts.
Site Manager: Login Timeout (min.) parameter: page A-9
Site Manager: Password Timeout (min.) parameter: page A-10
Site Manager: Command Timeout (min.) parameter: page A-10
Site Manager: Login Retries parameter: page A-10