Configuring Dial Services
4-20
Parameter: Secondary Clock
Default: Internal
Options: Internal | Port 1 Ext Loop | Port 2 Ext Loop | Auxiliary Ext
Function: Identifies the secondary source of the transmit timing used by the single
port on the MCT1-1 Link Module and by both ports on the MCT1-2 Link
Module only if the primary clock becomes unavailable.
Internal Generated by the clock chip on the Link Module
Port 1 Ext Loop – Generated by the signal coming in from Port 1
Port 2 Ext Loop – Generated by the signal coming in from Port 2
Auxiliary Ext – Generated from an external source using the DB9
interface
The internal and external clock source options include loop timing from
either port or an auxiliary timing source using the DB9 connector.
Instructions: Specify the source of the secondary transmit clock.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.1.1.5
MCT1/MCE1 Port Parameters
After the clock parameters, Site Manager displays the MCT1 or MCE1 Port
Parameters window (Figure 4-14 or Figure 4-15).
The port parameters apply to each of the 23 DS0 channels (MCT1) or 30 DS0
channels (MCE1) provided by an individual MCT1/E1 connector.
1. Click on OK to accept the default values or modify the parameters
according to the parameter descriptions starting on page 4-22 or
page 4-27.