Vista de página 304
Customizing Backup Circuits
308621-14.00 Rev 00
13-23
Using Site Manager
To remove backup service:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Backup Circuits
. The Backup Circuits menu opens.
3. Choose
PPP
or
Frame Relay
. The Primary Circuit Definition window or
the FR Primary Interface Definition
window opens.
4. Click on
Cct Type
or
Intf. Type
. The Circuit Options window or the FR
Interface window opens.
5. Modify one of the following parameters:
For PPP, change the
Circuit Type
parameter to
Normal
.
Click on
Help
or see the parameter
description on page A-67.
For frame relay, change the
Interface
Type
parameter to
Normal
.
Click on
Help
or see the parameter
description on page A-72.
Site Manager asks you to confirm the
change, and then removes the backup
circuit and treats the leased circuit as a
regular circuit.
6. Click on
OK
. You return to the Circuit Options or the
FR Interface window.
7. Click on
Done
. You return to the Configuration Manager
window.