Configuring Dial Services
13-6
308621-14.00 Rev 00
Modifying the Frame Relay Backup Interface
After you configure a primary circuit, Site Manager sets up the frame relay
backup circuit with default values. The interface parameters define the frame relay
characteristics of the circuit, unlike the primary interface parameters, which define
the behavior of the backup circuit.
To modify the frame relay backup interface:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Dialup
.
The Dialup menu opens.
2. Choose
Backup Circuits
. The Backup Circuits menu opens.
3. Choose
Frame Relay
. The FR Primary Interface Definition
window opens.
4. Click on
Backup Def
. The FR Backup Interface window opens.
5. Optionally, set the following parameters:
Mgmnt Type
Address Type
Address Length
Polling Interval
Full Enquiry Interval
Error Threshold
Monitored Events
Multicast
Congestion Control
Congestion Timer
Congestion Counter
Hangup on DLCMI Failure
Click on
Help
or see
Configuring Frame
Relay Services
for parameter descriptions.
6. Click on
Done
. You return to the FR Primary Interface
Definition window.
7. Click on
Done
. You return to the Configuration Manager
window.