Terminating and Resetting the Circuit
The
max-uptime-termination
parameter automatically deactivates the circuit if
the call reaches the maximum time that you specify using the
max-uptime
parameter. If the router receives data after the circuit is down, the router does not
establish a demand connection.
To enable the max-uptime-termination parameter, navigate to the demand-circuit
prompt and enter:
max-uptime-termination
enabled
The default is disabled.
For example, to ensure the demand circuit to phoenix is disconnected after the
maximum amount of time, enter:
demand-circuit/to-phoenix#
max-uptime-termination enabled
The
uptime-termination-reset
parameter determines the amount of time the
router waits before making the demand circuit available again after an uptime
termination. The circuit is not established at this point, but the next time the router
receives data, the circuit will be available and the router can activate it. The router
invokes this timer only when you set the
maxtime-uptime-termination
parameter.
To specify when the demand circuit is reset after termination, navigate to the
demand-circuit prompt and enter:
uptime-termination-reset
<
integer
>
integer
is a number from 1 to 999,999 minutes. The default is 60 minutes.
For example, to reset the circuit after 30 minutes, enter:
demand-circuit/to-phoenix#
uptime-termination-reset 30