Configuring WAN Line Services
A-38 117021-A Rev. A
Parameter: Remote HDLC Address
Path: Configured MCE1 or MCT1 Connector > MCE1/T1 Logical Lines
Default: 7
Options: DCE
| 2 | DTE | 4 | 5 | 6 | 7
Function: Specifies the 1-byte HDLC address of this logical line. DCE is an address of 1;
DTE is address 3.
Instructions: Select DCE, DTE, or specify an explicit address value.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.17
Parameter: Rate Adaption
Path: Configuration Manager > QMCT1 Connector > MCT1 Logical Lines
Default: 56K LSB
Options: 64K
| 56K MSB | 56K LSB | 9.6K | 19.2K
Function: Sets the number of data bits transmitted and their bit positions within the
timeslot to achieve the data rate. The term “Rate Adaption” means that by
setting this parameter, you are adapting to the rate of your subscriber; the
software does not change the rate dynamically.
The 64K, 56K MSB, and 56K LSB options specify full DS0 rates. The 64K
option specifies that all 8 bits within the time slot carry data. Both 56K options
specify that 7 of the bits within the time slot carry data. If you select MSB, the
most significant bit carries framing overhead. If you select LSB, the least
significant bit carries framing overhead.
The 9.6K and 19.2K options specify DS0A subrates for an SDLC connection.
Choose one of these options only if you installed a QMCT1 DS0A link module.
The 9.6K option specifies a DS0A subrate of 9.6 Kb/s. The 19.2K option
specifies a DS0A subrate of 19.2 Kb/s. If you choose one of these options, you
may assign only one logical line to a time slot.
Instructions: Set the value to match the data rate between the subscriber’s host and CPE.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.6.1.18