Configuring WAN Line Services
A-26 117021-A Rev. A
MCT1 Port Application and Clock Parameters
Parameter: Line Impedance
Path: ASN MCE1 Connector > Edit Logical Lines > Port Details > MCE1 Port
Parameters
Default: 120 Ohm
Options: 120 Ohm
| 75 Ohm
Function: For the ASN MCE1 net module only, specifies line impedance.
Instructions: Set the line impedance.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.3.1.20
Parameter: Port Application Mode
Path: Unconfigured MCT1 Connector > Port Application
Default: NONPRI
Options: NONPRI
| PRI
Function: Specifies the application that the logical lines of this port provide.
Instructions: Select NONPRI to indicate that all the lines have a permanent circuit number
and are for leased lines, Frame Relay, or permanent connections for other
non-ISDN PRI applications.
Select PRI to indicate that the lines are for switched circuits using ISDN.
MIB Object ID: 1.3.6.1.4.1.18.3.4.9.1.16