Configuring SDLC Services
4-14 114053 Rev. A
Parameter: Receive Buffer Pool Size
Default: 7
Range: 1 through 255
Function: Sets the receive buffer pool size, that is, the number of buffers you want to
preallocate for receiving frames from the line.
Instructions: Enter the number of buffers you want for the receive buffer pool. You can
enter a value from 1 through 255; however, we recommend that you
accept the default, because increasing the receive buffer pool size uses up
more memory.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.2.1.34
Parameter: Initial Flow Control Credit
Default: 7
Range: 1 through 50
Function: Regulates the flow of data from the SDLC device to the SDLC interface.
Instructions: Accept the default. This parameter is reserved for future enhancements.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.2.1.9
Parameter: Enable Stats Collection
Default: TRUE
Options: TRUE
| FALSE
Function: Turns statistics collection on or off for this port.
Instructions: Enter TRUE to enable statistics collection; otherwise, enter FALSE.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.7.2.1.35