Customizing BootP
308644-14.00 Rev 00
4-5
Specifying a Minimum Timeout Value
By default, the router immediately forwards BOOTREQUEST packets to the
destination address in the BootP relay forwarding table. You can configure the
router to wait before forwarding a BOOTREQUEST packet out an interface. If the
value in the seconds field of a BOOTREQUEST packet is less than the value
configured on the interface, the router drops the packet.
The default minimum timeout value is 0 seconds. You can specify a value from 1
through 65,535 seconds (equivalent to 18 hours, 12 minutes, and 15 seconds).
To specify the minimum timeout value, complete the following tasks:
4. Choose
Relay Agent Interface Table
. The BOOTP Relay Agent Interface Table
window opens. This window lists all the IP
interfaces that you configured for BootP
services on the router.
5. Set the
Hops
parameter.
Click on
Help
or see the parameter
description on page A-16.
6. Click on
Apply
.
7. Click on
Done
. You return to the Configuration Manager
window.
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose
Protocols
.
The Protocols menu opens.
2. Choose
IP
. The IP menu opens.
3. Choose
BOOTP
. The BOOTP menu opens.
4. Choose
Relay Agent Interface Table
. The BOOTP Relay Agent Interface Table
window opens. This window lists all the IP
interfaces that you configured for BootP
services on the router.
(continued)
Site Manager Procedure
(continued)
You do this System responds
Vista de página 102