Avaya Configuring ATM Services Manual do Utilizador Página 196

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 268
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 195
Configuring ATM Services
A-46 114056 Rev. A
Parameter: T310
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 10
Options: 1 through 60
Function: Defines the Call Proceeding Received timer value (in seconds). This timer
begins when the circuit receives a CALL PROCEEDING message from the
network.
If the signaling does not receive a CONNECT or RELEASE message before this
timer expires, it clears the connection for that virtual circuit.
Instructions: Accept the default, 10, or enter a value from 1 through 60.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.28
Parameter: T313
Path: Configuration Manager > Protocols > ATM > ATM Signaling
Default: 4
Options: 1 through 24
Function: Defines the Connect Sent timer value (in seconds). This timer begins when the
circuit sends a CONNECT message to the network.
The Connect Sent timer stops when the circuit receives a CONNECT
ACKNOWLEDGE message from the network (indicating the completion of the
ATM connection for that interface).
If the timer expires before the circuit receives a CONNECT ACKNOWLEDGE
message, the circuit clears the connection.
Instructions: Accept the default, 4, or enter a value from 1 through 24.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.29
Vista de página 195
1 2 ... 191 192 193 194 195 196 197 198 199 200 201 ... 267 268

Comentários a estes Manuais

Sem comentários