Customizing Signaling
114056 Rev. A 9-5
T309 10 1 through 540 Defines the SAAL Data Link Connect timer value (in seconds).
This timer begins when a Signaling AAL malfunction occurs.
The SAAL Data Link Connect timer stops when the circuit
reestablishes SAAL (that is, when the circuit sends an
AAL-ESTABLISH-REQUEST and receives an
AAL-ESTABLISH-CONFIRM message).
If the timer expires before the circuit can reestablish SAAL, the
circuit clears the connection.
T310 10 1 through 60 Defines the Call Proceeding Received timer value (in
seconds). This timer begins when the circuit receives a CALL
PROCEEDING message from the network.
If the signaling does not receive a CONNECT or RELEASE
message before this timer expires, it clears the connection for
that virtual circuit.
T313 4 1 through 24 Defines the Connect Sent timer value (in seconds). This timer
begins when the circuit sends a CONNECT message to the
network.
The Connect Sent timer stops when the circuit receives a
CONNECT ACKNOWLEDGE message from the network
(indicating the completion of the ATM connection for that
interface).
If the timer expires before the circuit receives a CONNECT
ACKNOWLEDGE message, the circuit clears the connection.
(continued)
Table 9-1. Signaling Timer Descriptions
(continued)
Name Default Range Description