Customizing Signaling and ILMI Control VCs
114056 Rev. A 11-7
Modifying the Maximum AAL CPCS SDU Size
The maximum AAL CPCS SDU value defines the maximum packet size you
intend the control VC to transmit or receive.
Setting the Transmit SDU Size
We suggest that you accept the default value of 4608 bytes for maximum AAL
CPCS SDU size that the control VC supports in the transmit direction. Most
packet sizes fall well within this limit. However, you can set this value from 1
through 65535 bytes.
Setting the Receive SDU Size
We suggest that you accept the default value of 4608 bytes for maximum AAL
CPCS SDU size that the control VC supports in the receive direction. Most
packet sizes fall well within this limit. However, you can set this value from 1
through 65535 bytes.
Site Manager: Maximum AAL CPCS Transmit SDU Size: page A-59
Site Manager: Maximum AAL CPCS Receive SDU Size: page A-60